| Water-cooled compressors series WP 5000 |
| Final pressure 250 bar |
| Type |
Stage |
Cylinder |
Speed |
Charging
Capacity |
Power
required |
Weight |
Dimensions mm |
Frequenzy |
|
. |
. |
U/min |
m³/h (FAD) |
kW |
kg |
Length |
Width |
Hight |
Hz |
| WP 5500 |
4 |
4 |
1170
1470
1770 |
53
66
81 |
14,2
21,6
26,0 |
930 |
970 |
810 |
1325 |
60
50
60 |
| WP 5000 |
4 |
4 |
1170
1470
1770 |
105
133
162 |
28,5
43,2
52,0 |
1650 |
1215 |
1095 |
1570 |
50
60
50 |
Performance data with 5% tolerance, referred to 20° C and an air pressure of 1013 mbar.
Charging Capacity according to international navy standards.
Performance data on final pressure deviating from 30 bar upon request.
Weights and dimensions for standard units with three-phase A. C. motor, IP 54, and flexible mounting.
Cooling water requirement referred to a Δ t = 10 K